Technical Performance Data

Dualtherm © SOLAR unit configuration (6 – 16 -6) Visible Light Energy Factors Solar Factor Shading Coefficient U – value Colour Rendition
Outer Leaf Inner Leaf Total Light Transmission % External Reflection % Direct Transmission % External Reflection % Absorption % g value SC Air W/m ² K Argon (90%) W/m ² K Appearance
GREY FLOAT LOW E 39 6 28 11 61 0.36 0.41 1.4 1.1 Grey
BRONZE FLOAT LOW E 43 7 30 12 58 0.37 0.43 1.4 1.1 Bronze
GREEN FLOAT LOW E 65 10 33 9 58 0.4 0.47 1.4 1.1 Green
BLUE FLOAT LOW E 47 7 26 7 67 0.33 0.38 1.4 1.1 Blue
STOPSOL ON CLEAR LOW E 55 36 37 39 24 0.45 0.52 1.4 1.1 Silver
STOPSOL ON GREY LOW E 26 12 19 15 66 0.26 0.3 1.4 1.1 Silver Grey
COOL-LITE ST150 LOW E 45 19 30 20 45 0.36 0.42 1.4 1.1 Blue
SOLAR NEUTRAL 67 LOW E 58 19 41 22 38 0.48 0.55 1.4 1.1 Neutral
SOLAR SILVER GREY 32 LOW E 28 22 18 20 61 0.24 0.27 1.4 1.1 Silver Grey
SOLAR ROYAL BLUE 20 LOW E 19 18 13 19 68 0.18 0.21 1.4 1.1 Royal Blue
SOLAR SILVER 20 LOW E 19 34 12 33 55 0.17 0.19 1.4 1.1 Silver
SOLAR BRONZE 20 LOW E 19 17 11 20 68 0.16 0.18 1.4 1.1 Bronze
SOLAR SILVER 08 LOW E 8 43 6 35 59 0.09 0.11 1.4 1.1 Silver